Re: [MW:5572] swsi IQI wire

By all means acceptable

--- On Sun, 13/6/10, krishna <wiqw@rediffmail.com> wrote:

From: krishna <wiqw@rediffmail.com>
Subject: [MW:5570] swsi IQI wire
To: materials-welding@googlegroups.com
Date: Sunday, 13 June, 2010, 1:29 PM

HI frnds,
Here we have a job of wall thickness of 11mm (SWSI) we are using IQI 10 ISO 16.
so for 2 % sensitivity 11x2% =0.22
if we see the chart of wire type IQI there is no 0.22 wire dia but
while review of film we see 4th wire i.e 0.20 so is it acceptable or not.
thnx,