Thursday, June 10, 2010

Re: [MW:5526] Charpy for A53

what is your code of construction and thickness involved? and also provide MDMT, not operating temperature.

On Thu, Jun 10, 2010 at 7:13 PM, Emilio Cerato <ecerato@hotmail.com> wrote:

Dear All
I need to do a WPS for piping, This pipe drives ammonia.
Is necesary to do impact test?
The material is ASTM A53 GrB
The temperature of operation is -30ºC
I use E7018-1 for weld.
Thanks
 
Emilio Cerato



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...