Thursday, June 3, 2010

Re: [MW:5372] ER316 & E316-16 FOR CRYOGENIC SERVICE

MDMT is -196 degree c


From: "raghurambathula@gmail.com" <raghurambathula@gmail.com>
To: "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
Sent: Wed, June 2, 2010 8:27:35 PM
Subject: RE: [MW:5363] ER316 & E316-16 FOR CRYOGENIC SERVICE


What is ur MDMT?
Sent from my Nokia phone
-----Original Message-----
From: veloumany siva
Sent:  02/06/2010 8:41:33 pm
Subject:  [MW:5355] ER316 & E316-16 FOR CRYOGENIC SERVICE

Dear all,


one of our Client specification says"Qualification on Material Gr.316 also qualifies for Gr.316L but not Vice versa"

I want to esatblish WPS for Stainless steel Material Gr.316 (cryogrnic service) as per B31.3


My query is

whether  ER316 for GTAW Process and E316-16 for SMAW  will meet the Impact requirement?
 
 
Regards,
S.Veloumany


     

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...