Tuesday, June 1, 2010

RE: [MW:5327] Electrode for SA516 Gr.70 Material.

General (G classified) electrodes are brand specific, can't be used as just E XXXX-G, pl verify mfr datasheet, if it gaurantees impact enegy @ desired temperature, you may use, but specific to that brand name only.

Sent from my Nokia phone
-----Original Message-----
From: Vijay
Sent: 31/05/2010 9:23:26 pm
Subject: Re: [MW:5323] Electrode for SA516 Gr.70 Material.

Dear All,
Can we use E7018-G electrode??

Regards,
Vijay

On Mon, May 31, 2010 at 9:06 AM, KOLA Ramalingeswara Rao <krraoind@gmail.com
> wrote:

> As per ASME Sec II part C, E7018 electrode impact test up to minus 30
> degrees C. You can use E7018-1 for minus 46 degree C.
>
> Regards,
>
> K.Ramalingeshwara rao.
>
> On Sun, May 30, 2010 at 9:17 PM, Vijay <k.vijayaraj@gmail.com> wrote:
>
>> Dear All,
>>
>> Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at
>> -46 oC) or we need to use other??
>>
>> Kindly clarify.
>>
>> Regards,
>> Vijay,
>> Advanced Oilfield Technology Company,
>> Oman.
>>
>> --
>> To post to this group, send email to materials-welding@googlegroups.com
>> To unsubscribe from this group, send email to
>> materials-welding-unsubscribe@googlegroups.com
>> For more options, visit this group's bolg at
>> http://materials-welding.blogspot.com/
>> The views expressed/exchnaged in this group are members personel views and
>> meant for educational purposes only, Users must take their own decisions
>> w.r.t. applicable code/standard/contract documents.
>>
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...