Thursday, June 17, 2010

[MW:5637] Welding Procedure

 

 

 

Folks,

We doing  Mockup procedure before actual welding, what type tests are required to qualify the welding procedure

 

 I was looking for welding procedures for and filler metals

 CS A-106-B and 2 ¼ Cr ,

CS A-106-B and 410

CS A-106-B and 13 Cr

CS A-106-B and 9CR

 

Thanks , Bashbhat

 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...