Hi
Anbody knows, please share the details about welding compitability of
ASTM  A252 Grade 2 and Grade 3. group not listed in AWS D.1.1.
Filer metal selction also.This steel pipe pile work for LNG tank.
 
Thank You.
Best Regards
Sekar.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...