Friday, May 14, 2010

RE: [MW:5166] Change in welding consumable when impact is required

You can use ER70S-2 without requalification, since you are using a classification which exhibits greater toughness or recommended for lower temperature than the one used during procedure qualification.
QW 404.12 (e) applicable in your case.

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Muhammed Ibrahim
Sent: Thursday, May 13, 2010 9:09 PM
To: materials-welding@googlegroups.com
Subject: [MW:5165] Change in welding consumable when impact is required

Dear Members,
 
Please provide a clarification on the following query.
 
One PQR is qualified with GTAW+SMAW,  ER 70S-3+E7018-1 and impact tested at-46.
 
Impact testing is required for the job at -29 Deg.C. Can I use ER70S-2 instead of ER70S-3 ?.
 
As per ASME Sec.II C, ER 70S-3 supports up to -20 Deg C & ER 70S-2 Supports up to -30 Deg.C.
 
Is QW 404.12 applicable in this change?.
 

Thanks & Regards
Muhammed Ibrahim PK

 


No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...