Re: [MW:5075] Hydrotest of Piping System

Hi all,
           Considering the Hydro test (Strength Test) ie 1.5 times the design pressure it should be carried out one time only for the maximim extent .Many customer specifications implement this requirement. Say for example in PDO specs it's a requirement.
 
Regards,
Vaithiyanathan


 
On Wed, May 5, 2010 at 8:27 AM, Prabhu Kumar L <l.prabhukumar@saipem-india.com> wrote:
Dear All,

Further to the trailing mail, I would like to add some more points. The
basic criteria for any hydrotest (piping, equipment or pipeline) is that
the hydro test pressure shall not exceed 0.9 times of yield strength of
the materials which is being hydro tested.

The maximum hydro test pressure is arrived based on factor of safety
multiplied by the times of design pressure. For ex. All onplot piping,
the factor of safety is 0.6 and hydro test pressure is 1.5 times of
design pressure. Hence, 0.6 x 1.5 = 0.9, same way for pipeline, the
factor of safety is 0.72 and hydrotest pressure is 1.25 times of design
pressure, which comes 0.9. (the times of design pressure may vary
depends on factor of safety)

It means that at any point of time the hydrotest pressure shall not
exceed 90% of yield strength of the material and also it is decided
based on design factor or factor of saftey. If it exceeds this limit,
the material shall undergo permanent/ plastic deformation and this shall
not be rectified. Hence as long as the hydro test pressure is within
this limit, the system will work (immaterial of number of times).

Regards,

L. Prabhu kumar,
Sr. Principal Engineer,

Equipments & Materials Dept.,
Saipem India Projects Limited,
Nungambakkam High Road, Chennai - 600 034, India.
Tel:+91 44 43906588, Ext.: 588, Fax:+91 44 66840345,
Mobile Ph. No.: +91 9003010978.

L. Prabhu kumar,
Sr. Principal Engineer,

Equipments & Materials Dept.,
Saipem India Projects Limited,
Nungambakkam High Road, Chennai - 600 034, India.
Tel:+91 44 43906588, Ext.: 588, Fax:+91 44 66840345,
Mobile Ph. No.: +91 9003010978.

-----Original Message-----
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of Darcy Morin
Sent: Tuesday, May 04, 2010 7:49 PM
To: materials-welding@googlegroups.com
Subject: Re: [MW:5064] Hydrotest of Piping System

Further, ASME B31.3 utilizes a 3:1 safety factor in the Allowable
Stress Design of piping systems. So, it is unlikely that a 150%
hydrotest will weaken the system.



On 2010-05-04, at 0:37, Kathalingam Babu <kathalingam.qaqc@ppl.com.sg>
wrote:

> Hi
>
> On top of below mail, the materials will be weaken only if the test
> pressure exceeds the yield strength of the materials.
>
> In all codes, the test pressure will consider the above fact and
> test temperature, so the weakening of materials is rare if you
> follow appropriate fabrication procedures.
>
> Consideration shall be given what was the cause of failure, rather
> than how many time hydrotest allowed.
>
> Rgds,
>
> K.Babu
>
>
> ----- Original Message ----- From: "Kathalingam Babu"
<kathalingam.qaqc@ppl.com.sg
> >
> To: <materials-welding@googlegroups.com>
> Sent: Tuesday, May 04, 2010 2:22 PM
> Subject: Re: [MW:5042] Hydrotest of Piping System
>
>
>> Hi
>>
>> For your info, if the system fails , it doesn't mean, your weaking
>> the materials.
>>
>> I don't think , there is any restriction on how many times the
>> hydrotest allowed.
>>
>> Rgds,
>>
>> K.Babu
>> Singapore
>>
>>
>> ----- Original Message ----- From: "dhinesh gnanadhas"
<dhineshlhmm@gmail.com
>> >
>> To: "Materials & Welding" <materials-welding@googlegroups.com>
>> Sent: Tuesday, May 04, 2010 2:03 PM
>> Subject: [MW:5042] Hydrotest of Piping System
>>
>>
>>> Hi.
>>>
>>> If the piping system getting fails in every test. Howmany times we
>>> can
>>> do the hydro test for the same piping system?
>>>
>>> If we are doing the the hydrotest, we are weakening the pipe
>>> material.
>>> So, Howmany times the same system can be allowed to retest?
>>>
>>> --
>>> To post to this group, send email to
materials-welding@googlegroups.com
>>> To unsubscribe from this group, send email to
materials-welding-unsubscribe@googlegroups.com
>>> For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
>>> The views expressed/exchnaged in this group are members personel
>>> views and meant for educational purposes only, Users must take
>>> their own decisions w.r.t. applicable code/standard/contract
>>> documents.
>>>
>
>
> --
> To post to this group, send email to materials-
> welding@googlegroups.com
> To unsubscribe from this group, send email to
materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel
> views and meant for educational purposes only, Users must take their
> own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.


-------------------------------------------------------------------------------------------------------------------------------------------------------------------
DISCLAIMER: The information contained in this communication is intended solely for the use of the individual or

entity to whom it is addressed and others authorized to receive it. It may contain confidential or legally privileged

information. If you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution

or taking any action in reliance on the contents of this information is strictly prohibited and may be unlawful. If

you have received this communication in error, please notify us immediately by responding to this email and then

delete it from your system. Saipem India Projects Limited (SIPL) is neither liable for the proper and complete

transmission of the information contained in this communication nor for any delay in its receipt.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
With Best Regards

B.Vaithiyanathan

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...