Wednesday, May 12, 2010

[MW:5156] Re: Where to refer Acceptance Criteria for RI of Pressure Vessels

I had seen there Appendix 4 is only for Rounded indications porosity,
But what about Lack of fusion & undercut interpretation . ?
Can u pl mention particular appendix?

On May 11, 10:51 pm, "jacmzzz" <jacm...@prodigy.net.mx> wrote:
> For NDT evaluation, see mandatory apendices of Asme VIII D1
>
> Atentamente:
>
> Jorge Clemente
>
> De: materials-welding@googlegroups.com
> Para: "Materials & Welding" materials-welding@googlegroups.com
> Cc:
> Fecha: Tue, 11 May 2010 10:05:59 -0700 (PDT)
> Asunto: [MW:5142] Where to refer Acceptance Criteria for RI of Pressure Vessels
>
> > Dear All
>
> > Where we have to refer Acceptance criteria for Radiographic
> > Interpretation of weld joints of Pressure vessels in ASME VIII Div 1?
>
> > Like table 341.3.2 for B31.3 pressure piping,
> > Which section is for ASME Pressure Vessels ?
> > Which section & Where?
>
> > --
> > To post to this group, send email to materials-welding@googlegroups.com
> > To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
> > For more options, visit this group's bolg athttp://materials-welding.blogspot.com/
> > The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg athttp://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...