Monday, April 26, 2010

Re: [MW:4959] limitation for UT

As explained by Mr. Kale one shall take care that operators are not reporting the length more than the calculated length theoretically for one day / shift. 

In practical operators are exceeding these limits and there are chances that they miss some of the important indications.


On 25 April 2010 11:09, Ali Asghari <asghariali@rocketmail.com> wrote:
 
Dear All
is there any limitation length for Ultasonic examination in day?
regards




--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34874] ASME IX, groove weld during WQT limits for Fillet Weld production

Hi David,  There are two points in WQT. 1. Thickness of Base Metal -T 2. Thickness of Weld Metal -t When you use a combination of two proces...