Never heard of one. I'm sure there are plenty of people on this forum like me who have vast experience of viewing & interpreting radiographs. Any chance you could take a photo (of the radiograph) and post it here?

Declan

On 15/04/2010 15:46, Shashank Vagal wrote:
Hi all,
In one RT film we have a 10-12 mm spot with density 3.13. The weld density is 3.17 and the parent metal density is 3.3. It is apparently interpass LoF in the 2nd fill pass after hot pass (confirmed by UT, where the indication ht is approx 20%of DAC). Is there any or what is the criteria for acceptance/rejection based on density difference?
Rgds,
Shashank Vagal

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...