Saturday, April 17, 2010

[MW:4837] Query for incomplete welding

Dear All,
 
Please clarify below points.
 
 
The designed thickness for a plate to plate welding is 10 mm and actual thickness used in the production is 12 mm. welding requires Single side full penetration weld.
 
1) considering the above case is it acceptable  if  welding groove is filled  upto 10 mm thickness only considering complete penetration on root side.
 
2) Is it acceptable if complete 12 mm thk groove is filled and we have incomplete penetrartion of 2 mm on root side.
 
Please give Code reference(if any).
 
 
Thanks & Regards
 
Asad Azmi

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34832] Inquiry about Single Bevel with Back Grinding

Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...