Dear Hrishi,

 

In normal condition, weld joints doesn’t call for stabilizing heat treatment for stabilized grades like 321/321H/ 347/347H.

 

I come to know, some refinery applications wherein process licensors like Axen specifies, stabilizing heat treatment @ 900 DegC for 4 Hrs (Rate of cooling, depends on manufacturer), where the operating temp is 425- 850 deg C. The requirements of stabilizing heat treatment are applicable to raw materials only. However, the same cycle may be continued for weld also, after consultation with process licensor.

 

It has been observed that stabilizing properties are improved by heating @ 900 Deg C. It is worth to note that there is no test to check the whether, material is stabilized or not ?

 

Regards,

 

 

Jignesh  R Rana

Chief Engineer  - INSP. & EXP.

UHDE India Ltd. 

P Please don't print this e-mail unless you really need to


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of K.M Hrishikesan
Sent: 09 February, 2010 5:24 PM
To: materials-welding@googlegroups.com
Subject: [MW:4259] Requirement of stabilized PWHT in the case of ER 347

 

Hi friends

 

Is PWHT mandatory in the case of depositing stabilized weld metal using ER 347 for welding SA 312 TP 321 pipings?

If so what will be the cycle?

The typical application  is heater coil.

 

Regards

Hrishi

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Messages sent by email can be manipulated by third parties and are therefore generally not legally binding. This message contains confidential information that may be privileged or protected from disclosure. If you are not the intended recipient, please be advised that you have received this email by mistake. You are requested to notify us immediately by return email and delete this email from your system. Any use, copying, distribution or printing of information by the unintended recipient is strictly prohibited. Thank you.

Regd. Office: Uhde House, Vikhroli (West), Mumbai 400 083, India
Tel: 91-022-6796 8000, Fax: 91-022-2578 4327 Website: www.uhdeindia.com

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...