Monday, February 8, 2010

Re: [MW:4248] WPS without Impact Test

Hi,
 
Refer QW 405.2. If you qualify a welding procedure in 3G position, it will qualify in all position. The logic behind is, the maximum heat input will be in 3G position. If you proove the notch toughness in 3G, your weld is guaranteed in all position.
If impact testing is not required, you can qualify a Welding procedure in any position.
 
Regards,
Ibrahim

On 7 February 2010 13:26, Vikas Bhandari <vikas.bhandari349@gmail.com> wrote:
Hi
 
AS per SEC IX, If one WPS is qualified in 3G position for what other positions it is qualified (please give the reference clause).
 
Thanks
 
 
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Thanks & Regards
Muhammed Ibrahim PK

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...