Monday, February 8, 2010

Re: [MW:4247] WPS without Impact Test

vikas,
it's qualified for all positions.

regards,
vipin george

On Sun, Feb 7, 2010 at 5:26 PM, Vikas Bhandari <vikas.bhandari349@gmail.com> wrote:
Hi
 
AS per SEC IX, If one WPS is qualified in 3G position for what other positions it is qualified (please give the reference clause).
 
Thanks
 
 
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...