Wednesday, February 10, 2010

[MW:4276] MW: 4246] WPS without Impact Test]


 
 
-----Original Message-----
From: GOSWAMI Pradip -THERMAL
Sent: Monday, February 08, 2010 4:41 PM
To: 'pgoswami@quickclic.net'
Subject: [MW:4246] WPS without Impact Test]

Hi Vikas,

 

Following are the recommendations of ASME Sec-IX.

 

·         QW-405.2--Vertical-uphill progression (e.g., 3G, 5G, or 6G position) qualifies for all positions.

 

·         QW-404.4-For hard-facing and corrosion-resistant weld metal overlay, qualification in the 3G, 5G, or 6G positions, where 5G or 6G pipe coupons include at least one vertical segment completed utilizing the up-hill progression or a 3G plate coupon is completed utilizing the up-hill progression, shall qualify for all positions.

 

Basically  for procedure qualification 3G- up qualifies for all position. However same is not true for performance qualification..

 

Thanks.

 

 

Pradip Goswami,P.Eng

Senior Engineer/Specialist(Welding-Metallurgy)

Machine Dynamics & Component Integrity Dept.

Engineering & Training Services Division

ONTARIO POWER GENERATION Inc.

PO Box-2000, RR-55(South)

Nanticoke, Ontario,N0A1L0

Tel:-(519) 587-2201, Ext 3107--in Nanticoke

         (416) 231-4111, Ext 5925--in Kipling,Toronto

Fax: (519) 587-6814

Email-pradip.goswami@opg.com.

 

 

-----Original Message-----

From: pgoswami@quickclic.net [mailto:pgoswami@quickclic.net]

Sent: Monday, February 08, 2010 9:07 AM

To: GOSWAMI Pradip -THERMAL

Subject: [Fwd: [MW:4246] WPS without Impact Test]

 

---------------------------- Original Message ----------------------------

Subject: [MW:4246] WPS without Impact Test

From:    "Vikas Bhandari" <vikas.bhandari349@gmail.com>

Date:    Sun, February 7, 2010 8:26 am

To:      materials-welding@googlegroups.com

--------------------------------------------------------------------------

 

Hi

 

AS per SEC IX, If one WPS is qualified in 3G position for what other positions it is qualified (please give the reference clause).

 

Thanks

 

--

To post to this group, send email to materials-welding@googlegroups.com

To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com

For more options, visit this group's bolg at http://materials-welding.blogspot.com/

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED RECIPIENT(S) AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED, PROPRIETARY AND/OR CONFIDENTIAL. If you are not the intended recipient, you are hereby notified that any review, retransmission, dissemination, distribution, copying, conversion to hard copy or other use of this communication is strictly prohibited. If you are not the intended recipient and have received this message in error, please notify me by return e-mail and delete this message from your system. Ontario Power Generation Inc.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...