Wednesday, February 10, 2010

[MW:4272] MW 4259] Requirement of stabilized PWHT in the case of ER 347

Hi Hrishi,

 

Is NACE-RP-0170-2004-Protection of Austenitic S.S against polythoinic acid corrosion is referred as one of design specifications, for this job.

 

Appreciate your response.

 

Thanks.

 

Pradip Goswami, P.Eng

88,Garth Trails Crescent

Hamilton,Ontario, L9B2X1,Canada

Email-pgoswami@sympatico.ca

Email-pgoswami@quickclic.net

Tel-905-679-9677


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of K.M Hrishikesan
Sent: Tuesday, February 09, 2010 6:54 AM
To: materials-welding@googlegroups.com
Subject: [MW:4259] Requirement of stabilized PWHT in the case of ER 347

 

Hi friends

 

Is PWHT mandatory in the case of depositing stabilized weld metal using ER 347 for welding SA 312 TP 321 pipings?

If so what will be the cycle?

The typical application  is heater coil.

 

Regards

Hrishi

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...