Tuesday, February 9, 2010

[MW:4259] Requirement of stabilized PWHT in the case of ER 347

Hi friends
 
Is PWHT mandatory in the case of depositing stabilized weld metal using ER 347 for welding SA 312 TP 321 pipings?
If so what will be the cycle?
The typical application  is heater coil.
 
Regards
Hrishi
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34874] ASME IX, groove weld during WQT limits for Fillet Weld production

Hi David,  There are two points in WQT. 1. Thickness of Base Metal -T 2. Thickness of Weld Metal -t When you use a combination of two proces...