Saturday, January 23, 2010

Re: [MW:4138] Is PCN L-III is qualified to certify ASNT L-II ?

Be care full the asme code does not recognise pcn. You have to establish a written practice acc. To sntc 1a and then qualify the ndt personnel. All exams etc must be based on asme sect v


  From: Arunachalam A [arunvani@gmail.com]
  Sent: 22/01/2010 21:24 ZE4
  To: materials-welding@googlegroups.com
  Subject: Re: [MW:4135] Is PCN L-III is qualified to certify ASNT L-II ?


NO




On Fri, Jan 22, 2010 at 8:30 PM, Chandra, Vasanthan (Lagos) <Vasanthan.Chandra@deltaafrik.com> wrote:

Friends,

 

Can any one Pl confirm that PCN L-III is qualified to certify ASNT L-II? If yes, Pl provide me reference document.

 

Regards,
Vasanth

 


*** WORLEYPARSONS GROUP NOTICE *** "This email is confidential. If you are not the intended recipient, you must not disclose or use the information contained in it. If you have received this email in error, please notify us immediately by return email and delete the email and any attachments. Any personal views or opinions expressed by the writer may not necessarily reflect the views or opinions of any company in the WorleyParsons Group of Companies."
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
ARUNACHALAM.A
050-5257122

"If you open your heart, love opens your mind."

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...