Wednesday, January 6, 2010

[MW:3976] RE: 3975] Allowable Nozzle Loads on Sulfur Storage tanks,

Please refer API 650 Appendix P

 

Best Regards,

Sunil Agrawal


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Ohm-Srinivasulu. K
Sent: Wednesday, January 06, 2010 10:28 AM
To: materials-welding@googlegroups.com
Subject: [MW:3975] Allowable Nozzle Loads on Sulfur Storage tanks,

 

Hi connoisseurs,

 

We are designing a Sulfur tank (13.6m ID X 14m H), similar to an existing tank, the existing

tank doesn't have allowable loads on jackted 4"x6" nozzles, How to calculate the allowable

loads, API-650 does not deal with small tanks.

 

Thanks & Regards,

Srinivas

Sr.Piping Engg.



ohm guru namasivaya

 


No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...