Especially on NPS 6 and above, heat input becomes problematic. One issue could be that your welders are using cosmetic 'wash' passes with GTAW on the cover pass of the weld. These welds should be performed with a maximum of 2 passes.  

Also, re-work in localized areas of welds (RT or PT failure for example) may neccesitate the cut-out of entire welds, piping sections and fittings in order to meet code requirements, material specifications or end user requirements in the finished weld. 
 
ASME B31.3 limits "internal protrusions".

The piping and fitting specifications will limit the acceptable ID of the components which can be extrapolated from measuring the OD.
 
The end user may have service conditions which require minimal turbulence.

Finally, when measuring and determining the extent of the distortion, be cautious to differentiate between misalignment and 'cave-in' type distortion. 

Best regards,

Darcy Morin

API 570 Refinery Piping Inspector   
 



On 2009-12-11, at 20:16, "Rajak, Sanjib  (Bantrel Constructors)" <RajakS@BantrelConstructors.com> wrote:

Hi Guys,
Can anybody through a light on how to control distortion in thin wall Stainless Sch10s piping welding. Fit up looks absolutely good but after welding we see cave in on weld upto 5/32".what is the acceptable limit or is there any acceptance critiria for cave in condition.
Thanks,
Sanjib

This e-mail and any attachments may contain confidential and
privileged information. If you are not the intended recipient,
please notify the sender immediately by return e-mail, delete
this e-mail and destroy any copies.

Any dissemination or use of this information by a person other
than the intended recipient is unauthorized and may be illegal.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...