Tuesday, November 24, 2009

RE: [MW:3717] ASME B31.3 unlisted materials

The material is ASTM 519 Gr 4130

 

Best regards,

 

John Lock

Quality & Classification Engineer

Pacific Deepwater Construction Ltd

cid:image002.jpg@01CA4F2E.75D71400

Cellular.                 +82 (0)10 4693 6282

Office Tel.              +82 (0)55 631 9071

Office Fax.             +82 (0) 631 7499

E-mail                    j.lock@pacificdrilling.com

P Before printing I think about the environment

 

From: pgoswami@sympatico.ca [mailto:pgoswami@sympatico.ca]
Sent: Friday, November 20, 2009 10:08 PM
To: materials-welding@googlegroups.com
Subject: RE: [MW:3705] ASME B31.3 unlisted materials

 

What is the unlisted material, could you be specific, i.e could you please provide speficication or composition etc.
 
Thanks.
 
Pradip Goswami,P.Eng
Welding & Metallurgical Engineer/Specialist.
Ontario Power Generation Inc.
Toronto, Canada.
 
> Date: Thu, 19 Nov 2009 23:43:10 -0800
> Subject: [MW:3695] ASME B31.3 unlisted materials
> From: jjlock53@gmail.com
> To: materials-welding@googlegroups.com
>
> Should PWHT requirements for the materials type be followed for
> unlisted materials ie no P or S number?
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...