Hi:

May be there are some reason like:

1°) Dirty base metal (Clean joint faces and adjacent surfaces)

2°) Dirty filler electrode (Use specially cleaned and packaged electrode, and store it clean area)

3°) High solidification rate (Use preheat or increase heat imput)

 

4°) Inaproper arc length, welding current, or electrode manipulation (Change welding conditions and techniques)

 

 

 About the redry electrode, follow the recomendation from supplier

 Regards

Antonio Ruscitto

 

On Sab Nov 7 13:55 , mahen dran sent:

 

Hi,
 
I am mahendra from KSA.
 
using 316L oerilicon electrode over 316L plate ((Flange joints - thickness around 8 mm)),
which creates porosity issue sometimes here . WPS and PQR are followed properly and there are no significant variation.
The electrode supplier suggests to use it in rebake oven.
 
We knows low hyd. electrodes  which  are ending  with 5,6 and 8 are to be used  with oven.
Is it correct way or normal proceudeure to use the SS electrode in oven ?
What is the control parameter to eliminate the porosity issue after  welding (Especially in  SS plate)
 
mahendra.t



 

 



*********************************************************************

¡IMPORTANTE!

Para evitar accidentes por inhalación de monóxido de carbono:

- Mantenga los ambientes ventilados en forma permanente.

- Revise que la llama sea color azul y uniforme.

- Instale y haga revisar periódicamente sus artefactos sólo a través de gasistas matriculados.

Recuerde que los artefactos a gas pueden emitir Monóxido de Carbono: un gas altamente tóxico e imperceptible.

Más consejos en http://www.metrogas.com.ar

*********************************************************************

Este mensaje es privado y confidencial y va dirigido sólo al destinatario indicado. Si lo ha recibido por error, por favor avísenos inmediatamente vía e-mail a error-mail@metrogas.com.ar y tenga la amabilidad de eliminarlo de su sistema. La utilización o divulgación de su contenido puede importar la comisión de un delito. No copie, reproduzca o divulgue -en forma parcial o total- su contenido. Cualquier opinión contenida, es exclusiva de su autor y no representa la opinión de MetroGAS S.A. - Muchas gracias.

This message is private and confidential and it is only intended for the addressee named above. If you have received this message and it is not addressed to you, please advise us immediately at error-mail@metrogas.com.ar and kindly remove it from your system. The use or disclosure of its contents may be regarded as an offense. Do not copy, reproduce or disclose them, either partially or fully. Opinions are the exclusive responsibility of the author and do not represent the opinion of MetroGAS S.A. - Thank you.

:: http://www.metrogas.com.ar

 


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...