Wednesday, November 4, 2009

[MW:3590] Re: WELD DISTANCE

Hi Ranjith,
                    In ASME which section have this detail. Give detail to let us know.
 
A.Louis
Welding Inspector
CB&I Lummus and Toyo JV
Singapore

--- On Wed, 4/11/09, ranjith kumar <ranjithmajestic@gmail.com> wrote:

From: ranjith kumar <ranjithmajestic@gmail.com>
Subject: [MW:3583] WELD DISTANCE
To: materials-welding@googlegroups.com
Date: Wednesday, 4 November, 2009, 3:03 PM

Dear phirke

According to ASME SEC toe to toe u should maintain 4x thickness of pipe
--
Regards

R.RANJITHKUMAR
QA/QC Engineer,






Connect more, do more and share more with Yahoo! India Mail. Learn more
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...