Wednesday, November 4, 2009

[MW:3588] Re: Minimum Distance Between two welds

the minimum distance between 2 welds is normally the thickness of the parent material being welded
 
regards,
 
Nick Davies
 


 
On Wed, Nov 4, 2009 at 8:01 AM, Phirke, Praphulla D (GE Infra, Oil & Gas) <praphulla.phirke@ge.com> wrote:


Dear All,
Anyone know where I can find the minimum distance to be maintained
between two welds ?
Please let me know

Thanks
Praphulla






--
Regards,

Nick Davies

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...