Chaitanya ,

Find out whether this is cross country pipeline or belongs to any petrochemical plant , because code limitation will differ , ASME B 31.3 has calculations about Blind flange , but size may limited


Thanks & Best Regards,

Vinayak Kale
E & C  DIv. QA & I , OGSP
Larsen And Toubro Ltd
Powai , Mumbai
vinayak_kale@lntenc.com
Ph No.+91- 67053805/3685
Fax No. +91-67051988
(M) - + 91 9892743803



Chaitanya Purohit <chaitanya_purohit@yahoo.co.in>
Sent by: materials-welding@googlegroups.com

09/27/2009 07:06 PM

Please respond to
materials-welding@googlegroups.com

To
Material Welding <materials-welding@googlegroups.com>
cc
Mithun.Murali@dodsaldxb.ae
Subject
[MW:3336] Hydrotest flange thickness calculation





Dear Friends,

Please help to reply to the below query....

---------- Forwarded message ----------
From: Mithun Murali <
Mithun.Murali@dodsaldxb.ae>
Date: 2009/9/27
Subject: Query regarding Hydrotest flanges
To:
chaitanya_purohit@yahoo.co.in

Hi Chaitanya,

Can you ask this query in the group as I am unable to do so.

Any calculation sheet or method available for Thickness calculation for Blind Flange for 64 " CS pipeline hydrotest.(test pr of 83 barg), 400# rating.

I had referred to one of the Client spec, which demands 170mm thick plates for the same.

Any reference of Agency or Consultant doing these kind of Calculations.

 

Thanks and regards,

Mithun

Design Engineer - Piping

Dodsal Engineering & Construction Pte. Ltd.

Dubai, U.A.E.

Phone : +9714-3161279




Disclaimer :This email and any files transmitted with it are intended solely for the use of the addressee(s) only and may contain confidential and/or privileged information. If you are not the addressee, then this message is not intended for you and be advised that you have received this email in error and that any use , dissemination , forwarding, printing or copying of this email is strictly prohibited. In such case please notify the sender and delete this email and any attachments with it from your system immediately.Receipt of this email by you shall not give rise to any liability on the part of Larsen & Toubro Limited

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...