Hi,

I have tried in the past for mock up using Kobelco and Metrode GTAW Flux Cored wires. At site it depends upon accessbility of weld joint and welder skill .

If possible , purge the joint with argon / nitrogen and weld with GTAW flux cored wire .

Regards,
Alagu



On Tue, 22 Sep 2009 14:25:35 +0530 wrote>Dear members We have typical vessel (site assembly), where backing gas arrangement could not be done for a stainless steel joint due to Safety (confined space), as well as space constraint.One of the options will be using flux cored wire for GTAW.Please share your view on these consumables for root pass of GTAW Stainless steel; where backing gas application is impractical, any body used these consumables?Kobleco is manufacturing these wires under TGX series, any other manufactures who has similar product for this application?
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...