[MW:3244] Re: Shelf life of Low hydrogen electrodes

Hello Ravindra,

ASME Section II C says the below;

"6.2 The shelf-life requirement shall be a minimum of
six (6) months from date of manufacture when stored
in its original unopened container. Alternate minimum
storage periods shall be as agreed upon between the supplier
and purchaser."

Please check with supplier for further details

Thanks
Senthil


On Sep 17, 2:58 pm, Ravindra T <indra.t...@gmail.com> wrote:
> Dear All
>
> Our contractor has brought low hydrogen electrodes (E 7018 & 8018) which are
> manufactured in 2007 for welding station piping in one of our intermediate
> pump station of our cross country pipeline project. I would like to know
> whether these electrodes can be used now?. Is there any reference in ASME
> code regarding the expiry/ shelf life of Electrodes?
>
> Please advise me in this regard.
>
> Thanking you all in advance
>
> Ravindra