Dear all ,
I have SA 694 F2 grade flange and during tacking with SA 106 Gr B pipe the tack gets crack , consumable used is ER 70S .
Can anybody suggest what could be the reason and what is the solution .
With Best Regards
Dinesh Tiwari
From: BR <raghurambathula@gmail.com>
To: Materials & Welding <materials-welding@googlegroups.com>
Sent: Saturday, June 13, 2009 4:22:40 PM
Subject: [MW:2424] Re: SA 694
it belongs to same grouping (S1G1), hence no seperation quaification
required for F52. you can use the procedure qualified using X52 pipes.
On Jun 13, 4:07 pm, Ali Asghari <asghari...@rocketmail.com> wrote:
> hi
> what is equivalent for SA 694 F52(FLANGE) ?
>
> this flangis is welded with pipe 4" (made from X52).THERE IS qualified wps for welding X52 pipes.
> is there needed to run a PQR FOR THIS JOINT?
> REGARD ADVANCE
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---