Dear All,
 
we are working as per API 5L 44th edition in our new project, and order is for linepipe inspection, during charphy V notch test we got acceptable impact value but shear area was brittle, then i refered QAP completely, there is acceptance criteria only for impact value not for shear area, i also refered API 5L 44th edition but there was same.
 
So please can anybody tell me about this, should i accept this?

--
Regards,

Kevin Sanchala
ABS industrial Verification India Pvt. Ltd.
Mob: +91-9725467645
       +91-9979112969

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---