Hi!
Actually the welders skill and joint fit up plays major role in avoiding Porosity in addition to proper baking of electrodes, cleaning of weld joint, air draft on the job .etc
I presume the porosity intensity is more in root and that is due to air get sucked during welding from opposite side of root joint.
i)Why not to try with reducing the root gap say from 0-1mm with root face of say 2mm . and welding with min weaving , with short arc.
Regards
Hegde P.B.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of TrueMalk@aol.com
Sent: Tuesday, June 09, 2009 4:07 AM
To: materials-welding@googlegroups.com
Subject: [MW:2361] Re: Prosity(2G)
Were both tests, 3G and 2G done within the environmental exposure limit times for low hydrogen rods?
-christian-
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---