[MW:2270] Re: Pl.Help.

It depends of the agreement at the contract stage. Usually inspector witness is 10% but must guarantee that 100% valves were tested before witness.

 

Fernando Gameiro

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of prashant pansare
Sent: quinta-feira, 28 de Maio de 2009 8:41
To: materials-welding@googlegroups.com
Subject: [MW:2267] Pl.Help.

 

Dear all,

I' ve inspected ball & NRV ( API 6D)  valves for xyz company.QAP was not available & client also not provided extent of check,but i inspected Hydro test 100% for body & 10% foe seat & released all the valves after satisfactory results.

My firm wants clarification for Why i not done 100% testing for seat also?

I' ve been warned,badly as i' ve carried out inspection without QAP & taken my own decision.

Is there any specs. or std. to rsolve this matter? & if available pl.forward me,so that i can

responce immediately to avoid further action.

Pl. help.

Regards to all ...PRASHANT    




Explore and discover exciting holidays and getaways with Yahoo! India Travel Click here!</a


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...