Wednesday, May 6, 2009

[MW:2104] Pump Performance Curve

hi,
 
                           We have got some centrifugal pumps for our project. Performance curve for the same is attached herewith. The pumps are manufactured as per API 610 10th Edition. Client is not accepting the pumps since it is not compying with Clause 5.1.14 of API 510.
 
 
Rated Flow: 250 m3/hr (requirement)
Centrifugal pump.
medium: Jet A1 Fuel.
 
               Can anybody help me out?
 
Regards
Prabhakar. S
Qatar. 

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...