I also couldn't find it anywhere in B31.3.
 
We are also facing the same problem in our project for IOCL Haldia. Code is silent about it.
 
In this case, the best way is to do additional NDT and hardness on these joints. especially hardness on the HAZ of joints to ensure that no hardening of HAZ occured.
 
Regards
Mukesh

On Tue, Feb 10, 2009 at 2:32 PM, Zameer Mohammed <dreamthinkwork@gmail.com> wrote:

Dear Mr. Nilesh,

 

Could you pls give the reference paragraph in the ASME B 31.3 which mentions this?

 

I heard it shall be 5t or min 300mm for the size of a pup piece. No where in the ASME B 31.3 I could see it mentioned. Correct me if I'm wrong.

 

Thank you,

 

Regards,

 

 

Sabir 



On Tue, Feb 10, 2009 at 11:28 AM, nilesh <nilesh_parsekar@yahoo.com> wrote:
Dear Javed,
 
   As per ASME 31.3 it should be 150mm

 Nilesh Parsekar,
 QC CO-ORDINATOR
(Dp Mech,API 510,API 570,AWS-CWI,NDT LEVEL2)
 Belleli Energy
 QATAR


--- On Tue, 2/10/09, Mohammad Javeed <mmubasharjaveed@gmail.com> wrote:
From: Mohammad Javeed <mmubasharjaveed@gmail.com>
Subject: [MW:1534] minimum length
To: materials-welding@googlegroups.com
Date: Tuesday, February 10, 2009, 1:09 AM


dear all, have a nice day
can any one tell me what is a  minimum length between two butt joints.( piece of pipe) with reference
thanks with regards
m javed








--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...