Sunday, December 14, 2008

[MW:1401] Interpass temperature measurement.


Dear Friends,

I have a confusion regarding the measurement of interpass temperature.During GTAW welding of Titanium material, interpass temperature should be maintained very low to avoid oxidation (Blue color formation). When weld length is more, the moment welder starts welding   interpass temperature exceeds the specified limit. Before welding with next rod, interpass temp will be higher than specified but generally  we won't stop welding until total run or weld length is completed.
 
Please advise me when to measure interpass temperature.  
Regards
 
P.K 

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...