Wednesday, December 3, 2008

[MW:1382] Re: WPS qualification

Group number is to be considered when impact is required.
 


 
2008/12/3 SHRIRAM PURANIK <stpuranik@gmail.com>
Can any body clarify for SA 240 TP 310S (P8 Gr. 2) + SA 240 TP321 (P8 Gr.1)  WPS to be separately qualified if I have separate qualified WPS and what filler wire to be used.
 
Regards,
 
S T Puranik

--
Shriram Puranik





--
Thanks & Regards
Muhammed Ibrahim PK

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...