[MW:1377] Re: Fwd: [MW:1374] Re: Calibration, Validation of welding machines as per BS 7570 standard.

pl. don't share any copy right material such as codes, company
standards etc in any public forum like this. instead you can just give
referance to a partcular para of code/std.

Thanking you all for coopeartion

On Dec 3, 6:55 am, "Purushottam Bhattacharya" <puru1...@gmail.com>
wrote:
> Dear All,
>
> Plz find review BS EN 17662-2005. Hope it helps !!! I tried to attach the
> std. but it exceeds the attachment limit.
>
> Normally, as a standard practice, we go for a *FUNCTION CHECK* for the
> welding machines i.e., using a calibrated Digital Clampmeter to check the
> output of the Welding machine after setting the required current/voltage
> paramaters, making sure before checking that the input supply to the welding
> machine is as per requirement (recording fluctuations in power supply, if
> any).
>
> Regards,
> Puru.
>
> On 12/2/08, Rituraj Bose <boser2...@gmail.com> wrote:
>
>
>
> > Dear Mr. Muniyandi,
>
> > Will you please inform where I can get the details of this frequencies
> > for calibration?
>
> > Regards,
> > R. Bose
>
> > On Dec 1, 12:22 pm, "Muni Andy" <cmkf...@gmail.com> wrote:
> > > Dear Friends,
> > > Welding equipments need calibration i e the ammeter and voltmeter is to
> > be
> > > calibrated.Frequency is once in 3 months.
> > > validation is required for the welding process and not for welding
> > > equipments.
> > > Regrds,
> > > C.Muniyandi
>
> > > On Mon, Dec 1, 2008 at 11:43 AM, <kata...@bilfal.com> wrote:
>
> > > > Dear friends,
>
> > > > I am not very clear about the words Calibration, Validation of welding
> > > > equipments.
>
> > > > Calibration is defined in some of the literature as all the operations
> > for
> > > > the purpose of determining the value or errors of a measuring
> > instruments.
> > > > (Checking the measuring instruments correctness such as A, V meters)
>
> > > > where as Validation is defined as all the operations for the purpose of
> > > > demonstrating that an item of Arc welding equipment or welding system
> > > > complies with the operating specification for that welding equipment or
> > > > syestem( Checking the correctness of equipment).
>
> > > > I seen many fabrication  shops  doing calibration not Validation.
>
> > > > BS 7575-2000  is also having titile  " Code of Practice for Validation
> > of
> > > > arc welding equipment".
>
> > > > Can any body  suggest me  wether welding equipment requires  Calibraion
> > or
> > > > Validation?
>
> > > > Regards
>
> > > > P.K- Hide quoted text -
>
> > > - Show quoted text -
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34832] Inquiry about Single Bevel with Back Grinding

Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...